Amman – Jordan00962785300152
Ayman Khateeb
Mechatronics Engineering
Saudi Arabia
Jordanian

(Date of birth not provided)

Electrical I&C Commissioning Engineer FACILITY OPERATION & MAINTENANCE MANAGER
Years of Experience: +15

Skills

Skills and Core Competencies

• PLC (Programmable Logic Control)
• SCADA system (Supervisor Control and Data Acquisition)
• DCS (Distribution Control System)
• HMI (Human Machine Interface)
• Sales skills
• Self-confidence.
• Self-motivation.
• Ability to adapt.
• Working under stress
• API 580/581, Risk Based inspection & Resource Document
• API 570/571, Pipe inspection & Corrosion material professional

Certificates

 Process Hazard Analysis (PHA)
 AutoCAD 2D Electrical Design
 Autodesk Revit design
 3D modeling software
 Rockwell Allen Bradly Programmer RS
Logic PLC Logic 5, 500 & 5000
 Schneider PLC Programmer
Yokogawa DCS “Centum VP course”
troubleshooting & Operation
Winterwear (In touch) programming
and troubleshooting

Languages

Arabic
English

Education

BSc Mechatronics Engineering
Al Balqa Applied University
2004 |Jordan

Professional Experience

Electrical I&C Commissioning Engineer
MARAFIQ
Feb.2014 - April.2024 |Saudi Arabia

Mar.2021 – April.2024

Electrical I&C Commissioning Engineer
Sep.2017 – Feb.2021
Waste water Treatment Plant O&M Leader
Feb.2014 – Aug.2017
RO Desalination Plant O&M Leader
Lead a team for Inspect the equipment, facilities and any other aspect of an engineering
project to ensure that it has been designed and installed correctly.
Lead projects, including RO seawater desalination, pump and lifting stations,
wastewater treatment plants, and the entire RAS ALKhair network piping. Ensure the
inclusion of all subsystems, such as MV/LV switchgear, IC looping, calibration, and
SCADA integration, following the IFC drawing & RC Standard design.
Leading RCA, PHA, RA and ability to establish PM schedules / procedures / inspection
reports.
 Lead the Operation maintenance activity during the warranty period for below system
(Lagoons with Air floatation, Aerators, SST, Blowers, Tertiary Filtration, Sludge
thickening, Sludge digestion and disinfection.
Develop and implement SOP, Annual CAPEX/OPEX Budget Presentation of monthly,
quarterly, and annual O&M reports, budget review and staffing report.
Improving the plant’s effluent compliance from 74 % only to 98 % compliance.
The Plant Configuration, Sand Filters, Microfilters, Ultrafiltration, RO Membrane,
Chlorine & Lim injection.

Pharmaceutical Facility Maintenance Leader
BAXTER PHARMACY
2009 - 2014 |Saudi Arabia

Adhere to the GMP, GDP & FDA manufacture standard, in addition to leading different
internal & external. Audits.
Provide guidance and mentorship the engineering team & manage day by day
maintenance activities.
Run the above-mentioned activities in harmony with proper documentation & record
keeping systems as well as international management system ISO 9001:2000 & Food
Safety standard ISO22000

Electro_ Mechanical Maintenance Leader
PROCTER & GAMBLE
2005 - 2009 |

provide front line maintenance leadership and maintenance related technical
support for the Power Block facility and act as the primary contact for I&C
maintenance related issues in the area of responsibility to build the team’s
knowledge in electrical control systems, PLCs, instrumentation, construction,
calibration, maintenance, and troubleshooting

Lead the Shift operation & maintenance team
Jordan Phosphate Maintenance Engineer
July.2004 – Aug.2005 |Jordan

Project Commissioning Engineer
Oversee the commissioning and installation of various equipment, systems, and facilities.
My role ensures that these components operate seamlessly and deliver the expected
outcomes. Below, I provide examples of projects I have been assigned:
Successfully replaced an air blower with a capacity of 31,500 m³/hr., incorporating a new
Variable Frequency Drive (VFD).
Oversaw the commissioning process for the potable and wastewater network piping at the
RAS Al-Khari facility.
Commissioning of RAS Al-Khari Seawater Cooling Pumping Station, with a capacity of 45
m³/hr.
Commissioning of RAS Al-Khari Sanitary Waste Treatment Plant which handles a capacity of
200,000 m³/day.
Commissioning of Jubail MV/LV Switchgear: medium-voltage (35.6 kV) and low-voltage
(4.16 kV and 480 V).
Commissioning of RAS Al-Khari Sanitary Lift Station Plant, handling 55,000 m³/day.
DIO Qualification for RO Modification at Baxter Pharmaceutical Plant: Conducted
qualification activities related to Reverse Osmosis (RO) modifications at the Baxter
pharmaceutical plant.
Operation & Maintenance Leader
As an operations and maintenance team leader, I have overseen critical aspects of
electrical transmission and distribution systems. My responsibilities included testing,
monitoring, installation, and troubleshooting of various equipment, utilities, energy
storage systems, control systems, and substations.
Allow me to provide specific examples of facilities I managed:
Seawater RO Desalination Plant (Capacity: 100,000 m³/day)
Potable Water Pump Station Plant (Capacity: 200,000 m³/day)
Upgrading Long & Short Conveyor Belt Maintenance Monitoring
Maintenance and Programming of Dumping Stations and Loss Weight Feeders using PLCs
Management of Critical Equipment at Baxter Pharma:
Boiler, Chiller, Cooling Towers, Air Furnace Operation, Sterilizer, Incubator Sample
Room, Clean Room HVAC System
Additionally, I led the P&G Operation & Maintenance team, overseeing chemical feeders to
agitators (mixers) and the drying process through air furnaces to produce powdered materials.